IntelliJ IDEA 2018.2 Help

Optional MIDP Settings Dialog

The dialog box opens when you click the Optional Settings button on Mobile SDK Specific Options page of the New Project From Scratch Wizard.

Use this dialog box to specify additional options that are not generally required. The contents of the dialog box depend on the mobile development tool used:

WTK

Item

Description

MIDlet-Description

In this text box, provide a description of your MIDlet suite.

MIDlet-Icon

In this text box, specify the location of the MIDlet suite presentation .png file within the .jar.

MIDlet-Data-Size

In this text box, type the minimum number of bytes of persistent data required by the MIDlet.

MIDlet-Info-URL

In this text box, specify the URL to access more information about the MIDlet suite and/or the vendor.

MIDlet-Delete-Confirm

In this text box, type the message to be shown when the user is prompted to confirm deletion of the MIDlet suite.

MIDlet-Install-Notify

In this text box, specify the URL to send POST request to confirm successful installation of this MIDlet suite.

User Defined Settings

In this area, compose a list of user-defined attributes related to specific MIDlets. For each attribute, specify a key and a value. Use the Add and Remove buttons to manage the contents of the list. Use the Move Up and Move Up buttons to define the order of settings. This order determines the priority in which the settings are applied.

DoJa

Item

Description

AppVersion

In this text box, specify the application version (10 bytes maximum).

ConfigurationVer

In this text box, specify the J2ME configuration version, for example, CLDC-1.0.

ProfileVer

In this text box, specify the version of the i-mode Java Application runtime environment profile, for example, DoJa-1.5oe.

SPsize

In this text box, specify the size of the ScratchPad in bytes.

AppParam

In this text box, specify the parameters of the main class (255 bytes maximum).

UseNetwork

In this text box, specify http for applications that use network functionality.

TargetDevice

Specify here a model name if the application is targeted to a particular model(128 bytes maximum). Do not set this option for applications targeted to all models.

LaunchAt

To have your application launched automatically at the specific time, specify the required time in this text box.

AppTrace

Choose the On value to have some information output using System.out.println() or System.err.println() after the i-Appli is terminated.

DrawArea

In this text box, specify the size of the application drawing area, for example, 120x130.

GetUtn

When this option is selected, the application refers to the handset identification code and IC chip information on its SIM or UIM card.